Description
Freeze protection or process temperature maintenance : 5° C – 65° C TubeTrace with FP self-regulating heating cable is designed, in order to protect against freezing and maintain the required temperature in the tube, where there is no possibility of exposure to high temperatures. FP heating cable is resistant to temperatures up to 85 ° C. Heating features with self-regulating FP heating cable
Available power density at 10 ° C ………….. 9, 15, 25, 32 W / m
Rated voltage……………………………………………………. 230 IN
Tube temperature range………………………………..from 5 ° C to 65 ° C
Maximum temperature of external influence on the cable1:
Permanently off…………………………………..85° C
Temperature class’
9, 15, 25 W / m……………………………………………Tb 85 ° C
32 W / m……………………………………………….Tb 100 ° C
With a stabilized design '……………….Tb 85 ° C